This RAID calculator shows usable capacity, efficiency and fault tolerance for RAID 0, 1, 5, 6, 10, 50 and 60. Enter the disk count, disk size and any hot spares, and it returns the numbers together with the formula it used. Use it to compare protection levels before you commit to a design, and to catch layouts that are not valid for a given level.
Result
The result updates automatically as you change any input.
Formula and worked steps
Formulas used
- RAID 0: usable = N x S
- RAID 1: usable = S (n-way mirror)
- RAID 5: usable = (N - 1) x S
- RAID 6: usable = (N - 2) x S
- RAID 10: usable = (N / 2) x S
- RAID 50: usable = (N - G) x S
- RAID 60: usable = (N - 2G) x S
- Efficiency = usable / (N x S)
- N = disks in the set excluding hot spares, S = size of one disk, G = number of groups (RAID 50/60).
- All disks are the same size. Mixed sizes are limited by the smallest disk in most implementations.
- Result is raw formatted-disk capacity before filesystem, metadata, vendor reserves or hot-spare policy.
- RAID 10 is 2-way mirrors. Guaranteed tolerance is the worst case; best case assumes failures land in different mirrors or groups.
- Minimum disks: RAID 0 = 2, RAID 1 = 2, RAID 5 = 3, RAID 6 = 4, RAID 10 = 4 (even), RAID 50 = 3 per group (2 groups min), RAID 60 = 4 per group (2 groups min). Some vendors enforce different minimums; check your array documentation.
What is RAID capacity?
RAID combines several disks into one logical volume and spends part of the raw space on redundancy. How much it spends, and how many failures the volume survives, depends on the level you pick.
Raw capacity
Raw capacity is the number of data-set disks multiplied by the size of one disk. The calculator lists hot spares separately, because a spare holds no data until a disk fails and then takes the failed disk’s place.
Usable capacity and efficiency
Usable capacity is what remains after mirroring or parity. Efficiency is usable capacity divided by raw capacity, shown as a percentage. It is the quickest way to compare how much of each purchased terabyte holds data.
Fault tolerance
Guaranteed tolerance is the number of failures the level survives in every case. Best-case tolerance is the most it can survive if the failures happen to land in different mirrors or groups. Design to the guaranteed figure.
How the RAID calculator works
In the formulas, N is the number of disks in the set (spares excluded), S is the size of one disk and G is the number of groups for RAID 50 and 60. The tool validates the layout first. It rejects RAID 10 with an odd disk count, RAID 6 with fewer than four disks, and RAID 50 or 60 where the disks do not divide evenly into groups.
Formulas by level
- RAID 0: usable = N x S, with no redundancy
- RAID 1: usable = S, because every disk holds a full copy
- RAID 5: usable = (N – 1) x S, one disk of parity
- RAID 6: usable = (N – 2) x S, two disks of parity
- RAID 10: usable = (N / 2) x S, striped 2-way mirrors
- RAID 50: usable = (N – G) x S, one parity disk per group
- RAID 60: usable = (N – 2G) x S, two parity disks per group
Worked example: eight 4 TB disks
Raw capacity is 8 x 4 = 32 TB. The levels then differ as follows.
| Level | Usable | Efficiency | Guaranteed failures survived |
|---|---|---|---|
| RAID 5 | 28 TB | 87.5% | 1 |
| RAID 6 | 24 TB | 75% | 2 |
| RAID 10 | 16 TB | 50% | 1 (up to 4 in the best case) |
Moving from RAID 5 to RAID 6 costs one more disk of space, 4 TB here, and buys one more guaranteed failure. Moving to RAID 10 costs a further 8 TB.
Worked example: RAID 50 and RAID 60
Take 12 disks of 4 TB in two groups of six. RAID 50 gives (12 – 2) x 4 = 40 TB usable, which is 83.3% efficiency, and survives one failure in each group. Sixteen disks in two groups of eight under RAID 60 give (16 – 4) x 4 = 48 TB usable, 75% efficiency, with two failures survived per group.
Why it matters for SAN and storage admins
Protection level drives cost per usable terabyte. A quick comparison shows how much extra raw capacity you buy for every additional failure you can survive, which is the number finance and risk teams both want. It also catches invalid layouts early, before they reach a vendor sizing tool or a change request.
For design reviews, the useful habit is to run the same disk set through every level you are considering and keep the table. The RAID calculator makes that a minute’s work, and the shareable link lets a reviewer reopen your exact inputs. Pair it with a performance check, because the level that wins on capacity can lose on write performance.
Typical uses of the RAID calculator include:
- Sizing a new pool or aggregate from a given number of drives.
- Checking how much space a move from RAID 5 to RAID 6 will cost.
- Estimating usable capacity for a quote before the vendor’s sizer is available.
- Explaining to stakeholders why raw and usable capacity differ.
Best practices and common mistakes
Capacity arithmetic is simple, so most errors come from what the arithmetic leaves out.
- Treat guaranteed tolerance as the design figure. Best-case tolerance depends on which disks fail.
- Convert TB to TiB if your array reports binary units, as the result is in the unit you enter.
- Leave room for filesystem, metadata and array reserves. The RAID calculator gives formatted-disk arithmetic only.
- Check your vendor’s supported group sizes, because many arrays limit disks per RAID group or stripe.
- Remember that larger disks take longer to rebuild, which lengthens the time you run with reduced protection.
- Do not count hot spares as usable space. They protect the set but add nothing to capacity.
- Re-run the numbers when you change the disk size, as efficiency depends only on layout but usable space scales with S.
A frequent mistake is to read RAID 10 tolerance as “half the disks can fail”. That is only true if each failure hits a different mirror pair. Two failures in the same pair lose the data, so the guaranteed figure is one.
FAQs
How do I calculate usable capacity in RAID 5?
Use (N – 1) x S. Eight 4 TB disks give 28 TB usable at 87.5% efficiency, with one disk’s worth of space spent on parity.
How many disks can RAID 6 lose?
Any two. Each stripe carries two independent parity blocks, so the data stays recoverable after two simultaneous disk failures. A third failure before a rebuild completes loses the volume.
Why is RAID 10 fault tolerance shown as two numbers?
One failure is always safe. More are survivable only when the failed disks sit in different mirror pairs, so the best case is half the disks and the guaranteed case is one.
Next, try the RAID parity overhead calculator, the IOPS calculator and the TB to TiB converter, or browse the full list of storage calculators.