This storage array comparison tool builds a side-by-side table from the figures you enter. It marks the best value in each row, shades rows where the arrays differ and exports the result as a CSV file. It contains no vendor data on purpose, so every number in your table comes from a datasheet or quote that you can cite, and every difference is one you can see.
Result
The result updates automatically as you change any input.
Formula and worked steps
Formulas used
- Rows ending in [max] or [min] mark the best numeric value in each row
- Rows are shaded when the arrays' values differ
- The tool contains no vendor data. Every figure is whatever you type, so cite your source and its date in the table.
- Numbers are read from the start of each cell, ignoring commas and units, so compare like with like.
What is an array comparison?
A comparison puts two or more arrays next to each other on the same attributes. Done well, it turns scattered datasheets into a decision. Done badly, it compares unlike figures and gives a false answer with confidence.
Attributes
Useful attributes cover capacity, performance, connectivity and features. Examples are usable capacity, maximum capacity, supported protocols, controller count, drive types, snapshot and replication features, rack units, power draw, support terms and price. The tool does not limit the rows.
Sources and dates
Specifications change with each software release. The tool encourages a row for source and date, so that every figure can be traced and rechecked. Without it, a table is a claim and not evidence.
Comparing like with like
The same label can mean different things. Raw and usable capacity differ, so do decimal and binary units, and so do performance numbers measured at different block sizes. The comparison is only as good as the care taken to match them.
How the storage array comparison tool works
Type or paste a comma-separated table. The first row holds the attribute heading and the names of the arrays. Each later row is an attribute followed by one value per array. Quote a cell if it contains a comma.
Marking the best value
End a row label with [max] or [min]. The tool then reads the number at the start of each cell, ignoring commas and units, and ticks the highest or the lowest. If two arrays tie, both are ticked. If all values are the same, nothing is ticked, since no array is better.
What to put in the table
A good table covers the questions a decision depends on. The list below is a starting point, and every row can be adapted.
- Capacity: raw, usable at your protection level, and maximum expandable
- Performance: IOPS and throughput with the test conditions, and latency
- Connectivity: protocols, port speeds and port counts
- Data services: snapshots, replication, data reduction, encryption
- Physical: rack units, power draw, cooling and weight
- Commercial: price, support terms, licences and warranty period
- Evidence: the source and date for each column
Showing differences
Rows where the arrays differ are shaded, so you can see at a glance which attributes actually separate them. Rows that match are the ones to ignore. The summary counts how many rows differ and how many cells are empty.
Worked example
Take three arrays with example figures: usable capacity of 100, 120 and 90 TB, and latency of 1.0, 0.8 and 0.8 ms. With [max] on capacity, the 120 TB array is ticked. With [min] on latency, both 0.8 ms arrays are ticked. A protocols row that reads “FC and iSCSI”, “iSCSI” and “NVMe/TCP” is shaded as different, and a row with identical values is left plain. The export contains the same grid.
Exporting and sharing
The CSV download gives you the grid exactly as you entered it, with the best-value markers kept in the row labels, so the file opens in a spreadsheet or can be pasted back into the tool later. The shareable link stores your inputs in the address, so a colleague sees the same table. Because the data lives in the link and not on a server, nothing you type is sent anywhere.
Why it matters for SAN and storage admins
Buying storage is a comparison exercise, and vendors present their strengths. A storage array comparison you build yourself, from sources you chose, keeps the process honest and repeatable. When someone asks later why an array was chosen, the table and its sources are the answer.
It also helps teams agree. Storage, network and application owners care about different rows. A shared table with the sources attached lets each person check the rows that matter to them, and argue about facts and not impressions.
Use it when you:
- Shortlist arrays for a purchase.
- Prepare a request for proposal scoring sheet.
- Document why a platform was chosen.
- Compare an upgrade with a replacement.
Best practices and common mistakes
- Add a row for source and date, and fill it in for every column.
- Use the same units and the same basis, such as usable capacity, in every column.
- Prefer measured or independently tested figures to marketing claims. “Up to” figures are best-case.
- Record the test conditions for performance, including block size, read and write mix and queue depth.
- Include costs beyond the purchase price, such as support, power, and licences.
- Keep the table with the decision record.
A storage array comparison is only as honest as its weakest row. A frequent mistake is to compare a headline number from one datasheet with a conservative number from another. If the bases differ, the comparison is invalid however neat it looks.
FAQs
Does the tool include vendor specifications?
No. It ships empty apart from example placeholders. Every figure is whatever you type, so you can cite your own sources and dates.
How does the tool mark the best value?
Add [max] or [min] to a row label. The tool reads the numbers in that row and ticks the highest or lowest. If every value is the same, nothing is marked.
How do I compare arrays fairly?
Compare the same thing on every column: usable not raw capacity, the same block size and read mix for performance, and the same support terms and period for cost.
Next, try the cost per GB storage calculator, the SAN vs NAS vs DAS selector and the RAID calculator, or browse the full list of storage calculators.