RAID Rebuild Time Calculator and URE Risk

This RAID rebuild time calculator estimates how long a rebuild takes, how long the array stays exposed, and how likely a read error is during the rebuild. Enter the RAID level, disk count and size, the rebuild rate and the share of it available under load. It is a quick way to see why large disks and wide RAID 5 sets worry storage teams.

Result

The result updates automatically as you change any input.

Formula and worked steps
Formulas used
  • Effective rate = rebuild rate x available share
  • Rebuild time = disk size / effective rate
  • Exposure window = rebuild time + time to replace the disk
  • Data read: RAID 1/10 = one disk; RAID 5/6 = (N - 1) disks
  • P(at least one URE) = 1 - exp(-bits read / 10^N)
Assumptions
  • The URE model assumes independent errors at the specified rate. Datasheet URE rates are specification limits, not measured rates for a given drive.
  • RAID 5 and 1 cannot correct a URE on the surviving data during a rebuild; RAID 6 can use its second parity; RAID 10 has no second copy of the affected block.
  • Rebuild rate depends on the controller, rebuild priority and host load. Use your array's observed rate.
  • 1 TB = 10^12 bytes.
References

What is a RAID rebuild?

When a disk fails, the array reconstructs its data onto a spare or replacement. Until that finishes, the group runs with reduced protection, so the time it takes is a window of risk.

Rebuild time

Rebuild time is the amount of data to write to the new disk divided by the rate at which the array can do it. The rate depends on the controller, the rebuild priority setting and how busy the array is with production I/O.

Exposure window

The exposure window is the whole period of reduced protection. It starts at the failure and ends when the rebuild completes, so it includes the time to notice, replace the disk and start the rebuild, plus the rebuild itself.

Unrecoverable read errors

An unrecoverable read error (URE) is a block the disk cannot return. Vendors specify a rate, such as one error per 10^14, 10^15 or 10^16 bits read. A rebuild reads large amounts of data, so the chance of meeting one is not small.

How the RAID rebuild time calculator works

The tool divides disk size by the effective rate to get the rebuild time, adds your response time for the exposure window, and then estimates how many bits must be read and the probability of at least one URE.

Formulas

  • Effective rate = rebuild rate x available share
  • Rebuild time = disk size / effective rate
  • Exposure window = rebuild time + time to replace the disk
  • Bits read: RAID 1 and 10 read one disk; RAID 5 and 6 read the other N – 1 disks
  • Probability of at least one URE = 1 – exp(-bits read / bits per error)

Worked example: an 8 TB disk

At 100 MB/s on an idle array the rebuild takes 8 x 10^12 / 100,000,000 = 80,000 seconds, or 22.2 hours. If production I/O leaves only half the rate, it takes 44.4 hours. If replacing the disk and starting the rebuild takes another 4 hours, the exposure window of the idle case is 26.2 hours.

Worked example: URE risk

In an eight-disk RAID 5 of 8 TB disks, a rebuild reads the seven survivors, 56 TB or 4.48 x 10^14 bits.

Datasheet URE rateChance of at least one URE
1 per 10^14 bits98.9%
1 per 10^15 bits36.1%
1 per 10^16 bits4.4%

A RAID 10 set reads only the mirror partner, 8 TB or 6.4 x 10^13 bits, so the figures drop to 47.3%, 6.2% and 0.64%.

What a URE means by level

In RAID 5 a URE on a surviving disk can make the rebuild fail or lose that block, because there is no second parity. RAID 6 can still correct it using the second parity. In RAID 10, a URE on the mirror partner loses that block, because no other copy exists.

Limits of the model

The probability formula treats errors as independent and uses the specified rate. Datasheet rates are limits and real drives often do better, so treat the result as a way to compare designs, not a forecast for a particular disk.

Why it matters for SAN and storage admins

Rebuild time is the part of RAID design that grows with every capacity generation. Disks get bigger much faster than they get faster, so rebuilds that once took an hour now take a day or more. The RAID rebuild time calculator puts that in numbers and shows why many teams choose RAID 6, smaller groups or erasure coding for large drives.

It also shows the value of operational speed. Replacing a failed disk in minutes instead of hours shortens the exposure window directly, and a hot spare removes the response time altogether. Rebuild priority is another lever, but raising it slows production I/O, so the right setting is a trade-off you can now quantify.

Use it when you:

  • Choose between RAID 5, RAID 6 and RAID 10 for large disks.
  • Estimate exposure windows for a risk assessment.
  • Justify hot spares and monitoring.
  • Explain why a bigger disk is not simply a better disk.

Best practices and common mistakes

  • Use the rebuild rate your array actually achieves, measured under load if possible.
  • Prefer RAID 6, or another scheme with double protection, for large disks in wide groups.
  • Keep hot spares, so the rebuild starts at once.
  • Run background scrubbing, often called patrol read, to find latent errors before a rebuild needs those blocks.
  • Do not treat a low URE probability as safe at fleet scale. A small chance across many arrays adds up.
  • Monitor rebuilds and alert on slow ones, since slow rebuilds lengthen the window.

A frequent mistake is to use the idle rebuild rate for planning. During business hours the available share can be far lower, and the window can double.

FAQs

How long does a RAID rebuild take?

Disk size divided by the effective rebuild rate. An 8 TB disk at 100 MB/s takes 22.2 hours when the array is idle and 44.4 hours if only half the rate is available.

What is a URE and why does it matter in a rebuild?

An unrecoverable read error is a block that cannot be read. A rebuild reads every surviving block, so one URE can fail the rebuild on RAID 5 or lose a block on RAID 10.

Does RAID 6 protect against UREs during a rebuild?

Yes. After one failure, RAID 6 still has a second parity to correct a bad block, so a single URE during the rebuild does not by itself lose data.

Next, try the RAID calculator, the RAID parity overhead calculator and the erasure coding calculator, or browse the full list of storage calculators.